Diagnostics and imaging in pregnancy
Topics
Diagnostic methods (§4.3)
Foetal assessment (§4.4)
Output
ECG and rhythm monitoring §4.3.1 · Rec Table 2
Rec Table 2 has no row for the ECG or rhythm monitoring.
Pregnant women may present changes in their surface electrocardiogram (ECG), including increased heart rate, minor leftward QRS axis shift (15–20 degrees), slightly decreased (20 ms) PR interval, prominent Q waves in II, III, and aVF, and flat or inverted T-waves in III, aVF, V1, V2, and V3 (Figure 1).
No class printed§4.3.1, printed p4484 [TXT]
A 12-lead ECG is part of the standard evaluation of pregnant women presenting with new-onset cardiac signs or symptoms or suspected arrhythmia. In pregnant women presenting with syncope or palpitations, long-term Holter monitoring or implantable loop recorders should be considered as additional diagnostic tools. As pregnant women are more prone to arrhythmias, the threshold to perform long-term ambulatory rhythm monitoring should be low.
No class printed§4.3.1, printed p4484 [TXT]
Diagnostic methods (§4.3)
The pros and cons of the primary cardiovascular diagnostic methods for diagnosing cardiovascular disease in pregnancy are described here. Pre-pregnancy evaluation is covered in the risk assessment section (Section 4.2.1).
No class printed§4.3, printed p4484 [TXT]
Educational summary of the 2025 ESC Guidelines. It does not replace clinical judgement or local protocol.